![]() ![]() This would not be related to "under treatment " it would be related to the infant's pathology. While it is common that treatment is prescribed as "intensive" phototherapy (based on aap guidelines), studies have shown clinical benefits can be derived from irradiance levels well below 10uw/cm2/nm.Įven when the light is functioning according to the prescribed phototherapy intensity, there may still be the need for adjunct therapy, regardless of the intensity. Phototherapy does not, in and of itself, expose a patient or user to significant hazard. Natus reported mdrs related to this issue because the neoblue 3 product risk analysis report indicated some potential risk of injury if the phototherapy intensity was not within specification.Ī clinical evaluation for "low-intensity" was conducted simultaneously with the investigation performed by the capa. This conversion chart has since been removed from the service manual. The investigation concluded that the root cause was in the conversion chart in the neoblue 3 service manual, and that the neoblue led phototherapy system units and olympic bili-meter radiometers were operating within specifications. This discrepancy led users to the incorrect conclusion that the neoblue 3 units were generating low intensity. Natus Medical Incorporated DBA Excel-Tech Ltd. distributed by Natus Medical Incorporated, its subsidiaries or affiliates. Prior to an ongoing natus capa, the service instructions for the neoblue 3 referenced the use of the olympic bili-meter radiometer as an alternate to the preferred neoblue radiometer.ĭue to technological differences, the bili-meter radiometer readings will differ from neoblue radiometer readings when measuring light output intensity from a neoblue led phototherapy system.Īs a convenience for neoblue 3 users and/or customers which already had the bili-meter, a conversion chart was provided in the neoblue 3 service manual.Ī root cause investigation, which took place in the natus capa process, confirmed that the target values listed for the bili-meter radiometer intensity readings in the neoblue 3 conversion chart were too high. The light output was factory calibrated with the neoBLUE Radiometer to provide an initial intensity of 35 ☓.5 W/ cm²/nm at the high setting and 15 ☒ W/cm²/nm at the low setting at a distance. The neoblue radiometer instead was designed specifically for measurement of the led light output spectrum generated by the neoblue products. neoBLUE LED Phototherapy Radiometer Natus Medical Incorporated (Natus) warrants to the initial Purchaser (Purchaser) that each new Warranted Product, as defined below, purchased hereunder will be free from defects in workmanship and materials for a period of one year (Warranty Period) from the date of its initial shipment to Purchaser. ![]() The olympic bili-meter was not intended to measure the narrow-spectrum light output generated by the newer led technology products like the neoblue 3. The olympic bili-meter radiometer is a legacy product designed to measure the broad-spectrum light output generated by older technology phototherapy products such as the olympic bili-bassinet. Natus technical service made multiple follow-up attempts to confirm the status of the neoblue 3 unit and received no response from the complainant. The complainant was sent a neoblue radiometer in replacement of their olympic bili-meter. ![]()
0 Comments
Leave a Reply. |